Model 40/40R
Single IR
Flame Detector
User Guide
FM, CSA Approved:
Class I Div. 1 Groups B, C, D
Class II/III Div. 1 Groups E, F, G
ATEX, IECEx Approved
Ex II 2 GD, EExde IIB+ H2 T5 (75°C)
Document ref: TM 40/40R, Rev (4) November 2010
218 Little Falls Rd., Cedar Grove, NJ 07009, USA
Phone: +1 (973) 239 8398 Fax: +1 (973) 239 761
Web-Site: www.spectrex.net
; Email: spectrex@spectrex.net
Zobrazit stránku 0
1 2 3 4 5 6 ... 75 76

Shrnutí obsahu

Strany 1 - Model 40/40R

Model 40/40R Single IR Flame Detector User Guide FM, CSA Approved: Class I Div. 1 Groups B, C, D Class II/III Div. 1 Groups E, F, G ATEX, IECEx Ap

Strany 2

SharpEyeTM Single IR Flame Detector User Guide x List of Figures List of Figures Figure 1: Field of View ...

Strany 3 - Warranty

TM 40/40R, Rev (4) November 2010 List of Tables xi List of Tables Table 1: Wiring Options ...

Strany 4 - Release History

SharpEyeTM Single IR Flame Detector User Guide xii List of Tables

Strany 5 - About this Guide

Overview 1 1 Introduction  In this chapter… Overview page 1 Model and Types page 2 Features and Benefits page 4 Principles of Operation page 4 Pe

Strany 6 - Abbreviations and Acronyms

SharpEyeTM Single IR Flame Detector User Guide 2 Model and Types 1.2 Model and Types The 40/40R is provided in various configurations depending on:

Strany 7 - Table of Contents

TM 40/40R, Rev (4) November 2010 Model and Types 3 Table 1: Wiring Options Wiring Option Connections Provided 1 Power Manual BIT Fault Relay N.C.

Strany 8

SharpEyeTM Single IR Flame Detector User Guide 4 Features and Benefits 1.3 Features and Benefits • Single IR Channel: Between 4.4 - 4.6 microns. •

Strany 9

TM 40/40R, Rev (4) November 2010 Principles of Operation 5 1.4.2 Heated Optics The SharpEye 40/40 Flame Detectors use heated optics. The heater in

Strany 10 - List of Figures

SharpEyeTM Single IR Flame Detector User Guide 6 Principles of Operation 1.4.5 Product Certification The 40/40R Flame Detectors have the following c

Strany 11 - List of Tables

TM 40/40R, Rev (4) November 2010 Performance Considerations 7 • This test includes functional test, environmental test, EMI/EMC test and software

Strany 12 - SharpEye

SharpEyeTM Single IR Flame Detector User Guide ii

Strany 13 - 1 Introduction

SharpEyeTM Single IR Flame Detector User Guide 8 Performance Considerations Table 2: Fuel Sensitivity Ranges Type Of Fuel Max. Distance ft. (m) Gas

Strany 14 - 40/40R X XXXX

TM 40/40R, Rev (4) November 2010 Performance Considerations 9 1.5.3 False Alarms Prevention To prevent false alarms, the detector will not alarm o

Strany 15

SharpEyeTM Single IR Flame Detector User Guide 10 Performance Considerations 1.5.4 Visual Indicators One 3-color LED indicator is located inside the

Strany 16 - 1.4 Principles of Operation

TM 40/40R, Rev (4) November 2010 Performance Considerations 11 1.5.5 Output Signals Outputs are available according to the default configuration o

Strany 17 - 1.4.2 Heated Optics

SharpEyeTM Single IR Flame Detector User Guide 12 Performance Considerations 1.5.6 Detector Status The possible detector function statuses are listed

Strany 18 - 1.4.5 Product Certification

TM 40/40R, Rev (4) November 2010 Internal Detector Tests 13 4 The Auxiliary Relay can be activated at the Warning level or Alarm level, depending

Strany 19 - 1.5.1 Detection Sensitivity

SharpEyeTM Single IR Flame Detector User Guide 14 Internal Detector Tests • Processor Watch dog • Software • Memory • Oscillator frequency Respo

Strany 20 - 1.5.2 Cone of Vision

TM 40/40R, Rev (4) November 2010 Internal Detector Tests 15 1.6.2.2 Automatic BIT The detector automatically performs a BIT every 15 minutes. A su

Strany 21

SharpEyeTM Single IR Flame Detector User Guide 16 Internal Detector Tests Table 10: Results of a Successful Manual BIT Output Result FAULT relay •

Strany 22 - 1.5.4 Visual Indicators

General Guidelines 17 2 Installing the Detector  In this chapter… General Guidelines page 17 Unpacking the Product page 18 Required Tools page 1

Strany 23 - 1.5.5 Output Signals

Legal Notice iii Legal Notice The SharpEye Optical Flame Detector described in this document is the property of Spectrex, Inc. No part of the hardwar

Strany 24 - 1.5.6 Detector Status

SharpEyeTM Single IR Flame Detector User Guide 18 Unpacking the Product • Environment: • Dust, snow or rain can reduce the detectors sensitivity a

Strany 25 - 1.6 Internal Detector Tests

TM 40/40R, Rev (4) November 2010 Required Tools 19 2.3 Required Tools The detector can be installed using general-purpose common tools and equipme

Strany 26 - 1.6.2 Built-In-Test (BIT)

SharpEyeTM Single IR Flame Detector User Guide 20 Certification Instructions 2.4 Certification Instructions Warning: Do not open the detector, even

Strany 27 - 1.6.2.3 Manual BIT

TM 40/40R, Rev (4) November 2010 Installation Cables 21 2.5 Installation Cables Follow the following guideline for the cable installation: • All

Strany 28

SharpEyeTM Single IR Flame Detector User Guide 22 Installing the Tilt Mount (part no. 40/40-001) 2.6 Installing the Tilt Mount (part no. 40/40-001)

Strany 29 - 2 Installing the Detector

TM 40/40R, Rev (4) November 2010 Installing the Tilt Mount (part no. 40/40-001) 23 2.6.1 Tilt Mount Specifications Table 13: USA Version Item Qt

Strany 30 - 2.2 Unpacking the Product

SharpEyeTM Single IR Flame Detector User Guide 24 Installing the Tilt Mount (part no. 40/40-001) Figure 5 shows the Tilt Mount Assembly with dimensi

Strany 31 - 2.3 Required Tools

TM 40/40R, Rev (4) November 2010 Connecting the Detector 25 2.7 Connecting the Detector This section describes how to connect the electric cablin

Strany 32

SharpEyeTM Single IR Flame Detector User Guide 26 Connecting the Detector 8 Check the wires for secure mechanical connection and press them neatly ag

Strany 33 - 2.5 Installation Cables

TM 40/40R, Rev (4) November 2010 Configuring your Detector 27 • 0-20mA is ‘Sink’ in option 1 and ‘Source’ in option 2 and 3. • 0-20mA 'Sour

Strany 34

SharpEyeTM Single IR Flame Detector User Guide iv Release History Rev Date Revision History Prepared by Approved by 0 July 15,2008 First Re

Strany 35 - 2.6.2 Tilt Mount Assembly

SharpEyeTM Single IR Flame Detector User Guide 28 Configuring your Detector • EOL – No • Heated Optics – Auto • Temperature – 41°F (5°C) 2.8.1 Al

Strany 36 - 2 Unpack the detector

TM 40/40R, Rev (4) November 2010 Configuring your Detector 29 2.8.3 Function Set-up You can select the desired functions as detailed in Table 16.

Strany 37 - 2.7 Connecting the Detector

SharpEyeTM Single IR Flame Detector User Guide 30 Configuring your Detector

Strany 38

Powering Up 31 3 Operating the Detector  In this chapter… Powering Up page 31 Safety Precautions page 32 Testing Procedures page 33 This chapter

Strany 39

SharpEyeTM Single IR Flame Detector User Guide 32 Safety Precautions 3.2 Safety Precautions After powering-up, the detector requires almost no atten

Strany 40 - 2.8.2 Address Set-up

TM 40/40R, Rev (4) November 2010 Testing Procedures 33 • USB RS485 Harness Kit P/N 794079-5. Refer to manual TM777050 for programming instruction

Strany 41 - 2.8.4 Heated Optics

SharpEyeTM Single IR Flame Detector User Guide 34 Testing Procedures  To perform Fire Simulator Test: 1 Power up the system and wait up to 60 seco

Strany 42

Maintenance 35 4 Maintenance and Troubleshooting  In this chapter… Maintenance page 35 Troubleshooting page 37 This chapter deals with preventive m

Strany 43 - 3 Operating the Detector

SharpEyeTM Single IR Flame Detector User Guide 36 Maintenance 4.1.2 Periodic Procedures In addition to preventive cleaning and maintenance, the dete

Strany 44 - 3.2 Safety Precautions

TM 40/40R, Rev (4) November 2010 Troubleshooting 37 4.2 Troubleshooting This section is intended to be a guide to correct problems which may happe

Strany 45 - 3.3 Testing Procedures

About this Guide v About this Guide This guide describes the SharpEye Model 40/40R Single IR Flame Detector and its features and provides instruction

Strany 46

SharpEyeTM Single IR Flame Detector User Guide 38 Troubleshooting

Strany 47 - 4.1 Maintenance

Appendices 39 Appendices

Strany 48 - 4.1.2 Periodic Procedures

SharpEyeTM Single IR Flame Detector User Guide 40 Appendices

Strany 49 - 4.2 Troubleshooting

Technical Specifications 41 A Specifications  In this appendix… Technical Specifications page 41 Electrical Specifications page 42 Outputs page 42

Strany 50 - 38 Troubleshooting

SharpEyeTM Single IR Flame Detector User Guide 42 Outputs A.2 Electrical Specifications Table 20: Electrical Specifications Operating Voltage Status

Strany 51 - Appendices 39

TM 40/40R, Rev (4) November 2010 Troubleshooting 43 • Option 3: Power, RS-485, 0-20mA (Source) and HART protocol, Fault Relay (N.O), Alarm Relay (

Strany 52 - 40 Appendices

SharpEyeTM Single IR Flame Detector User Guide 44 Outputs • HART Protocol The HART protocol is a digital communication signal at a low level on top

Strany 53 - A Specifications

TM 40/40R, Rev (4) November 2010 Troubleshooting 45 A.4 Mechanical Specifications Enclosure Stainless Steel 316 or Aluminum, heavy duty copper fr

Strany 54 - A.3 Outputs

SharpEyeTM Single IR Flame Detector User Guide 46 Environmental Specifications Salt Fog • Designed to meet MIL-STD-810C, method 509.1, procedure I

Strany 55

General Instructions for Electrical Wiring 47 B Wiring Instructions  In this appendix… General Instructions for Electrical Wiring page 47 Typical W

Strany 56

SharpEyeTM Single IR Flame Detector User Guide vi Abbreviations and Acronyms Abbreviations and Acronyms Abbreviation Meaning ATEX Atmosphere Expl

Strany 57 - A.6 Weight

SharpEyeTM Single IR Flame Detector User Guide 48 General Instructions for Electrical Wiring Table 25: Wiring length in feet (meter) Number of Detect

Strany 58

TM 40/40R, Rev (4) November 2010 Typical Wiring Configurations 49 B.2 Typical Wiring Configurations This section describes examples of typical wi

Strany 59 - B Wiring Instructions

SharpEyeTM Single IR Flame Detector User Guide 50 Typical Wiring Configurations Table 26: Wiring Connections Terminals Wiring Option Detector Model 5

Strany 60

TM 40/40R, Rev (4) November 2010 Typical Wiring Configurations 51 Figure 9: 0-20mA Wiring Option 1 (Sink 4-Wire) - Default Figure 10: 0-20mA W

Strany 61

SharpEyeTM Single IR Flame Detector User Guide 52 Typical Wiring Configurations Figure 11: 0-20mA Wiring Option 1 (Unisolated Sink 3-Wire) Figure

Strany 62

RS-485 Overview 53 C RS-485 Communication Network  In this appendix… RS-485 Overview page 53 C.1 RS-485 Overview By using the RS-485 network capab

Strany 63

SharpEyeTM Single IR Flame Detector User Guide 54 RS-485 Overview

Strany 64

Long Range Fire Simulator 55 D Accessories  In this appendix… Long Range Fire Simulator page 55 Tilt Mount - P/N 40/40-001 page 58 Weather Protect

Strany 65 - C.1 RS-485 Overview

SharpEyeTM Single IR Flame Detector User Guide 56 Long Range Fire Simulator D.1.1 Unpacking Verify that you have received the following contents: •

Strany 66 - 54 RS-485 Overview

TM 40/40R, Rev (4) November 2010 Long Range Fire Simulator 57 D.1.3 Range The 40/40R detector will trigger an alarm from a simulator, at a maximum

Strany 67 - D Accessories

Table of Contents vii Table of Contents Model 40/40R Single IR Flame Detector User Guide...iLegal Notice ...

Strany 68 - D.1.2 Operating Instructions

SharpEyeTM Single IR Flame Detector User Guide 58 Tilt Mount - P/N 40/40-001 D.1.5 Technical Specifications Mechanical • Explosion Proof Enclosure:

Strany 69 - D.1.4 Charging the Battery

TM 40/40R, Rev (4) November 2010 Weather Protection - P/N 777163 59 D.3 Weather Protection - P/N 777163 The weather protector protects the detect

Strany 70

SharpEyeTM Single IR Flame Detector User Guide 60 Air Shield - P/N 777161 D.4 Laser Detection Coverage Pointer - P/N 777166 The Laser Detection Cov

Strany 71

40/40R Optical Flame Detector 61 E SIL-2 Features  In this appendix… 40/40R Optical Flame Detector page 61 E.1 40/40R Optical Flame Detector This

Strany 72

SharpEyeTM Single IR Flame Detector User Guide 62 40/40R Optical Flame Detector E.1.2.1 Conditions for Safe Operating 1 The flame detector shall c

Strany 73 - E SIL-2 Features

TM 40/40R, Rev (4) November 2010 40/40R Optical Flame Detector 63 E.1.2.4 Other 1 The complete function of the flame detector (flame detection, fu

Strany 74

64 Technical Support Technical Support For all technical assistance or support, contact: 218 Little Falls Road Cedar Grove, NJ 07009, USA Tel: +1

Strany 75 - E.1.2.4 Other

SharpEyeTM Single IR Flame Detector User Guide viii Table of Contents 2.5Installation Cables.....

Strany 76 - Technical Support

TM 40/40R, Rev (4) November 2010 Table of Contents ix B Wiring Instructions..................

Komentáře k této Příručce

Žádné komentáře