Model 40/40M
Multi IR Hydrocarbon and Hydrogen
Flame Detector
User Guide
FM, CSA Approved
Class I Div. 1 Groups B, C, D
Class II/III Div. 1 Groups E, F, G
ATEX, IECEx Approved
Ex II 2 GD, Exde IIC T5 (75°C)
Document ref: TM 40/40M, Rev (6) July 2013
218 Little Falls Rd., Cedar Grove, NJ 07009, USA
Phone: +1 (973) 239 8398 Fax: +1 (973) 239 761
Web-Site: www.spectrex.net; Email: [email protected]et
Zobrazit stránku 0
1 2 3 4 5 6 ... 79 80

Shrnutí obsahu

Strany 1 - Model 40/40M

Model 40/40M Multi IR Hydrocarbon and Hydrogen Flame Detector User Guide FM, CSA Approved Class I Div. 1 Groups B, C, D Class II/III Div. 1 Groups E,

Strany 2

Multi IR Hydrocarbon and Hydrogen Flame Detector User Guide x List of Figures List of Figures Figure 1: Vertical Field of View for Gasoline ...

Strany 3 - Warranty

TM 40/40M, Rev (6) July 2013 List of Tables xi List of Tables Table 1: Wiring Options ...

Strany 4 - Release History

Multi IR Hydrocarbon and Hydrogen Flame Detector User Guide xii List of Tables

Strany 5 - About this Guide

Overview 1 1 Introduction ➣ In this chapter… Overview page 1 Model and Types page 2 Features and Benefits page 4 Principles of Operation page 4 Per

Strany 6 - Abbreviations and Acronyms

Multi IR Hydrocarbon and Hydrogen Flame Detector User Guide 2 Model and Types 1.2 Model and Types The 40/40M is provided in various configurations

Strany 7 - Table of Contents

TM 40/40M, Rev (6) July 2013 Model and Types 3 Table 1: Wiring Options Wiring Option Connections Provided 1 Power Manual BIT Fault Relay N.C. Alar

Strany 8

Multi IR Hydrocarbon and Hydrogen Flame Detector User Guide 4 Features and Benefits 1.3 Features and Benefits  Detects Hydrocarbons and Hydrogen

Strany 9

TM 40/40M, Rev (6) July 2013 Principles of Operation 5 The detector's principle of operation is based on the patented spectral analysis techn

Strany 10 - List of Figures

Multi IR Hydrocarbon and Hydrogen Flame Detector User Guide 6 Principles of Operation 1.4.4 RS-485 Modbus For more advanced communications, the 40/

Strany 11 - List of Tables

TM 40/40M, Rev (6) July 2013 Performance Considerations 7  For more details and guidelines for configuring, installing, operating and service –

Strany 12

Multi IR Hydrocarbon and Hydrogen Flame Detector User Guide ii

Strany 13 - 1 Introduction

Multi IR Hydrocarbon and Hydrogen Flame Detector User Guide 8 Performance Considerations Alarm response times for a standard fire at a specified ran

Strany 14 - 40/40M X XX X X

TM 40/40M, Rev (6) July 2013 Performance Considerations 9 1.5.2 Cone of Vision 1.5.2.1 Gasoline  Horizontal: 67°  Vertical: 70° Figure 1: V

Strany 15

Multi IR Hydrocarbon and Hydrogen Flame Detector User Guide 10 Performance Considerations Figure 2: Horizontal Field of View for Gasoline 1.5.2.2

Strany 16 - 1.4 Principles of Operation

TM 40/40M, Rev (6) July 2013 Performance Considerations 11 1.5.3 False Alarms Prevention To prevent false alarms, the detector will not alarm or

Strany 17 - 1.4.3 HART Protocol

Multi IR Hydrocarbon and Hydrogen Flame Detector User Guide 12 Performance Considerations Table 5: Welding Immunity Distance Sensitivity Setting Det

Strany 18 - 1.4.5 Product Certification

TM 40/40M, Rev (6) July 2013 Performance Considerations 13 1.5.5 Output Signals Outputs are available according to the default configuration or t

Strany 19 - 1.5.1 Detection Sensitivity

Multi IR Hydrocarbon and Hydrogen Flame Detector User Guide 14 Performance Considerations 1.5.6 Detector Status The possible detector function stat

Strany 20 - 1.5.1.3 Other Fuels

TM 40/40M, Rev (6) July 2013 Internal Detector Tests 15 4 The Auxiliary Relay can be activated at the Warning level or Alarm level, depending on

Strany 21 - 1.5.2 Cone of Vision

Multi IR Hydrocarbon and Hydrogen Flame Detector User Guide 16 Internal Detector Tests  Processor Watch dog  Software  Memory  Oscillator fr

Strany 22 - 1.5.2.2 Hydrogen

TM 40/40M, Rev (6) July 2013 Internal Detector Tests 17 1.6.2.2 Automatic BIT The detector automatically performs a BIT every 15 minutes. A succe

Strany 23

Legal Notice iii Legal Notice The SharpEye Optical Flame Detector described in this document is the property of Spectrex, Inc. No part of the hardwar

Strany 24 - 1.5.4 Visual Indicators

Multi IR Hydrocarbon and Hydrogen Flame Detector User Guide 18 Internal Detector Tests 1.6.2.3 Manual BIT The BIT is manually initiated by momentar

Strany 25 - 1.5.5 Output Signals

General Guidelines 19 2 Installing the Detector ➣ In this chapter… General Guidelines page 19 Unpacking the Product page 20 Required Tools page 21

Strany 26 - 1.5.6 Detector Status

Multi IR Hydrocarbon and Hydrogen Flame Detector User Guide 20 Unpacking the Product  Environment:  Dust, snow or rain can reduce the detectors

Strany 27 - 1.6 Internal Detector Tests

TM 40/40M, Rev (6) July 2013 Required Tools 21 2.3 Required Tools The detector can be installed using general-purpose common tools and equipment.

Strany 28 - 1.6.2 Built-In-Test (BIT)

Multi IR Hydrocarbon and Hydrogen Flame Detector User Guide 22 Certification Instructions 2.4 Certification Instructions Warning: Do not open the

Strany 29 - 1.6.2.2 Automatic BIT

TM 40/40M, Rev (6) July 2013 Installation Cables 23 2.5 Installation Cables Follow the following guideline for the cable installation:  All cab

Strany 30 - 1.6.2.3 Manual BIT

Multi IR Hydrocarbon and Hydrogen Flame Detector User Guide 24 Installing the Tilt Mount (part no. 40/40-001) 2.6 Installing the Tilt Mount (part n

Strany 31 - 2 Installing the Detector

TM 40/40M, Rev (6) July 2013 Installing the Tilt Mount (part no. 40/40-001) 25 2.6.1 Tilt Mount Assembly Figure 6 shows the Tilt Mount Assembly.

Strany 32 - 2.2 Unpacking the Product

Multi IR Hydrocarbon and Hydrogen Flame Detector User Guide 26 Connecting the Detector ➣ To install the Tilt Mount and Detector: 1 Place the tilt m

Strany 33 - 2.3 Required Tools

TM 40/40M, Rev (6) July 2013 Connecting the Detector 27 4 Use a ¾" – 14 NPT explosion-proof conduit connection or M25x1.5 flameproof gland t

Strany 34

Multi IR Hydrocarbon and Hydrogen Flame Detector User Guide iv Release History Rev Date Revision History Prepared by Approved by 0 July 15,2008 F

Strany 35 - 2.5 Installation Cables

Multi IR Hydrocarbon and Hydrogen Flame Detector User Guide 28 Connecting the Detector 2.7.1 Verifying the Detector Wiring The detector has five ou

Strany 36

TM 40/40M, Rev (6) July 2013 Configuring your Detector 29  The Fault output is N.C. energized SPST relay. The contacts are closed when the Detec

Strany 37 - 2.6.1 Tilt Mount Assembly

Multi IR Hydrocarbon and Hydrogen Flame Detector User Guide 30 Configuring your Detector  Heated Optics – Auto  Temperature – 41°F (5°C) 2.8.1

Strany 38 - 2.7 Connecting the Detector

TM 40/40M, Rev (6) July 2013 Configuring your Detector 31 2.8.4 Function Set-up You can select the desired functions as detailed in Table 17. Tab

Strany 39

Multi IR Hydrocarbon and Hydrogen Flame Detector User Guide 32 Configuring your Detector

Strany 40

Powering Up 33 3 Operating the Detector ➣ In this chapter… Powering Up page 33 Safety Precautions page 34 Testing Procedures page 35 This chapter d

Strany 41

Multi IR Hydrocarbon and Hydrogen Flame Detector User Guide 34 Safety Precautions 3.2 Safety Precautions After powering-up, the detector requires a

Strany 42 - 2.8.3 Address Set-up

TM 40/40M, Rev (6) July 2013 Testing Procedures 35 3.3 Testing Procedures This section describes the proof testing procedure for proper operation

Strany 43 - 2.8.5 Heated Optics

Multi IR Hydrocarbon and Hydrogen Flame Detector User Guide 36 Testing Procedures 2 Aim the Spectrex Fire Simulator Model 20/20-313 at the target

Strany 44

Maintenance 37 4 Maintenance and Troubleshooting ➣ In this chapter… Maintenance page 37 Troubleshooting page 39 This chapter deals with preventive

Strany 45 - 3 Operating the Detector

About this Guide v About this Guide This guide describes the SharpEye Model 40/40M Multi IR Flame Detector and its features and provides instructions

Strany 46 - 3.2 Safety Precautions

Multi IR Hydrocarbon and Hydrogen Flame Detector User Guide 38 Maintenance 4.1.2 Periodic Procedures In addition to preventive cleaning and mainten

Strany 47 - 3.3 Testing Procedures

TM 40/40M, Rev (6) July 2013 Troubleshooting 39 4.2 Troubleshooting This section is intended to be a guide to correct problems which may happen d

Strany 48

Multi IR Hydrocarbon and Hydrogen Flame Detector User Guide 40 Troubleshooting

Strany 49 - 4.1 Maintenance

Appendices 41 Appendices

Strany 50 - 4.1.2 Periodic Procedures

Multi IR Hydrocarbon and Hydrogen Flame Detector User Guide 42 Appendices

Strany 51 - 4.2 Troubleshooting

Technical Specifications 43 A Specifications ➣ In this appendix… Technical Specifications page 43 Electrical Specifications page 44 Outputs page 44

Strany 52 - 40 Troubleshooting

Multi IR Hydrocarbon and Hydrogen Flame Detector User Guide 44 Outputs A.2 Electrical Specifications Operating Voltage: 18-32 VDC Power Consumption

Strany 53 - Appendices 41

TM 40/40M, Rev (6) July 2013 Troubleshooting 45  Option 2: Power, RS-485, 0-20mA (Source) and HART protocol, Fault Relay (N.O), Alarm Relay, (N.

Strany 54 - 42 Appendices

Multi IR Hydrocarbon and Hydrogen Flame Detector User Guide 46 Approvals communicate between intelligent field instruments and the host system. HART

Strany 55 - A Specifications

TM 40/40M, Rev (6) July 2013 Troubleshooting 47 A.5 Mechanical Specifications Enclosure Stainless Steel 316 or Aluminum, heavy duty copper free

Strany 56 - A.3 Outputs

Multi IR Hydrocarbon and Hydrogen Flame Detector User Guide vi Abbreviations and Acronyms Abbreviations and Acronyms Abbreviation Meaning ATEX Atm

Strany 57

Multi IR Hydrocarbon and Hydrogen Flame Detector User Guide 48 Environmental Specifications Vibration  Designed to meet MIL-STD-810C, method 514.2

Strany 58 - A.4 Approvals

General Instructions for Electrical Wiring 49 B Wiring Instructions ➣ In this appendix… General Instructions for Electrical Wiring page 49 Typical

Strany 59

Multi IR Hydrocarbon and Hydrogen Flame Detector User Guide 50 General Instructions for Electrical Wiring Table 26: Wiring length in feet (meter) Nu

Strany 60

TM 40/40M, Rev (6) July 2013 Typical Wiring Configurations 51 B.2 Typical Wiring Configurations This section describes examples of typical wiring

Strany 61 - B Wiring Instructions

Multi IR Hydrocarbon and Hydrogen Flame Detector User Guide 52 Typical Wiring Configurations Table 27: Wiring Connections Wiring Option Detector Mod

Strany 62

TM 40/40M, Rev (6) July 2013 Typical Wiring Configurations 53 Figure 11: 0-20mA Wiring Option 1 (Sink 4-Wire) - Default Figure 12: 0-20mA Wiri

Strany 63

Multi IR Hydrocarbon and Hydrogen Flame Detector User Guide 54 Typical Wiring Configurations Figure 13: 0-20mA Wiring Option 1 (Non-isolated Sink

Strany 64

RS-485 Overview 55 C RS-485 Communication Network ➣ In this appendix… RS-485 Overview page 55 C.1 RS-485 Overview By using the RS-485 network capa

Strany 65

Multi IR Hydrocarbon and Hydrogen Flame Detector User Guide 56 RS-485 Overview

Strany 66

Long Range Multi IR Fire Simulator 57 D Accessories ➣ In this appendix… Long Range Multi IR Fire Simulator page 57 Tilt Mount - P/N 40/40-001 page

Strany 67 - C.1 RS-485 Overview

Table of Contents vii Table of Contents Model 40/40M Multi IR Hydrocarbon and Hydrogen Flame Detector User Guide ...

Strany 68 - 56 RS-485 Overview

Multi IR Hydrocarbon and Hydrogen Flame Detector User Guide 58 Long Range Multi IR Fire Simulator D.1.1 Unpacking Verify that you have received the

Strany 69 - D Accessories

TM 40/40M, Rev (6) July 2013 Long Range Multi IR Fire Simulator 59 D.1.3 Range Table 28: Sensitivity Ranges Sensitivity Detection Range (ft. / m

Strany 70 - D.1.1 Unpacking

Multi IR Hydrocarbon and Hydrogen Flame Detector User Guide 60 Tilt Mount - P/N 40/40-001 D.1.5 Technical Specifications Mechanical  Explosion Pr

Strany 71 - D.1.4 Charging the Battery

TM 40/40M, Rev (6) July 2013 Duct Mount P/N 777670 61 D.3 Duct Mount P/N 777670 The Duct Mount enables flame detection in areas where high temper

Strany 72

Multi IR Hydrocarbon and Hydrogen Flame Detector User Guide 62 Weather Protection - P/N 777163 D.4 Weather Protection - P/N 777163 The weather prot

Strany 73 - D.3 Duct Mount P/N 777670

TM 40/40M, Rev (6) July 2013 Laser Detection Coverage Pointer - P/N 777166 63 D.5 Laser Detection Coverage Pointer - P/N 777166 The Laser Detecti

Strany 74

Multi IR Hydrocarbon and Hydrogen Flame Detector User Guide 64 Laser Detection Coverage Pointer - P/N 777166

Strany 75

40/40M Flame Detector 65 E SIL-2 Features ➣ In this appendix… 40/40M Flame Detector page 65 E.1 40/40M Flame Detector This appendix details the sp

Strany 76

Multi IR Hydrocarbon and Hydrogen Flame Detector User Guide 66 40/40M Flame Detector E.1.2.1 Conditions for Safe Operating 1 The flame detector sh

Strany 77 - E SIL-2 Features

TM 40/40M, Rev (6) July 2013 40/40M Flame Detector 67 E.1.2.4 Other 1 The complete function of the flame detector (flame detection, function of

Strany 78

Multi IR Hydrocarbon and Hydrogen Flame Detector User Guide viii Table of Contents 2.5 Installation Cables ...

Strany 79 - E.1.2.4 Other

68 Technical Support Technical Support For all technical assistance or support, contact: 218 Little Falls Road Cedar Grove, NJ 07009, USA Tel: +1 (9

Strany 80 - Technical Support

TM 40/40M, Rev (6) July 2013 Table of Contents ix B Wiring Instructions..................